Appendix B: Default Programming - Fire-Lite MS-9200UDLS Manual

Addressable fire alarm control panel
Hide thumbs Also See for MS-9200UDLS:
Table of Contents

Advertisement

Appendix B: Default Programming

The following table provides a list of the programming options and their factory default settings.
Program Option
Detector Programming
Detector Type
Detector Verification
Detector Walktest
Detector PAS
Detector Presignal
Detector Zone Assign.
Detector Adj/Noun
Module Programming
Module Type
Module Walktest
Module Presignal
Module Zone Assign.
Module Adj/Noun
Zone 0 Enable
Zone 1 Enable
Zone 2 Enable
Zone 3 Enable
.........................through..........
Zone 96 Enable
Zones 97, 98 & 99
Loop Style
Loop Protocol
Trouble Reminder
Banner
Time Format
Hours Setting
Minutes Setting
Second Settings
AM-PM Setting
Month Setting
Day Setting
Year Setting
Daylight Savings
Month Start Daylight Savings
Week Start Daylight Savings
Month End Daylight Savings
Week End Daylight Savings
Verification
PAS Timer
Presignal Timer
Waterflow Retard Timer
NAC 1, 2, 3 & 4 Enable
NAC 1, 2, 3 & 4 Silenceable
NAC 1, 2, 3 & 4 Type
NAC 1, 2, 3 & 4 Sync Type
NAC 1, 2, 3 & 4 Autosilence
NAC 1, 2, 3 & 4 Coding
NAC 1, 2, 3 & 4 Zones
NAC 1, 2, 3 & 4 Silence Inhibit
Canadian Option Enabled
Waterflow Silenceable
MNS Override
169
Factory Default
Program Option
Not Installed
Relay 1
Smoke-Photo
Relay 2
Off
Relay 3
Yes
Annunciator Terminal Mode
No
Annunciator ACS Mode
No
UDACT
000 only
ACS Installed
none
Onboard DACT
Not Installed
Printer-PC
Monitor
Printer Baud
Yes
Service Terminal Panel ID
No
Ring Count
000 only
Primary Phone Type
none
Secondary Phone Type
Enabled
DACT Communication
Enabled
AC Loss Delay
Enabled
Backup Reporting
Enabled
Primary Reporting Style
.....................
Secondary Reporting Style
Enabled
Primary Account Code
Enabled
Secondary Account Code
Style 4
Primary 24 Hour Test Time
LITESPEED
Secondary 24 Hour Test Time
Off
Primary Phone Number
Secondary Phone Number
12 Hr
Primary DACT Format
12
Secondary DACT Format
00
ANN-Primary Enabled
ANN-Primary Modules Addr. 1 - 8
AM
ANN-Secondary Enabled
01
ANN-Secondary Modules Addr. 1 - 8
01
ANN-S/PG Port
00
ANN-S/PG Baud
Enabled
ANN-S/PG Data Bits
March
ANN-S/PG Parity
Week 2
ANN-S/PG Stop Bits
November
ANN-S/PG Offline Timer
Week 1
ANN-S/PG Printer Supervision
OFF
ANN-80 Piezo Enabled
0
ANN-80 Lock Enabled
0
ANN-80 Acknowledge Button Enabled
0
ANN-80 Silence Button Enabled
Enabled
ANN-80 Reset Button Enabled
Yes
ANN-80 Drill Button Enabled
Bell
ANN-I/O Point/Zone
System Sensor
ANN-I/O Range
0
ANN-I/O Active LEDs Only
Steady
ANN-RLY Relay 1
Zone 000 only
................through.......................
No
ANN-RLY Relay 10
No
ANN-LED Point/Zone
No
ANN-LED Alarms/ATS (Alarm, Trbl, Supv)
No
ANN-LED Range
MS-9200UDLS Series Manual — P/N 52750:H 4/14/2014
Factory Default
Alarm
Trouble (fixed)
Supervisory
No
No
No
No
No
No
9600
0000
0
Touchtone
Touchtone
OFF
2
First Available
Report Point
Report Point
0000
0000
0100
0200
Ademco Contact ID
Ademco Contact ID
No
None
No
None
9600
7
Even
1
60
No
Yes
Yes
Yes
Yes
Yes
Yes
Zone
00-29
Zone 1
............
Zone 10
Zone
ATS
0 - 9