Diagnostics; Discovery - Bonjour - Cisco Small Business 200 Series Administration Manual

Small business 200 series smart switch
Hide thumbs Also See for Small Business 200 Series:
Table of Contents

Advertisement

Administration

Diagnostics

Event
Cool down period after the
Critical threshold was
exceeded (all sensors are
lower than the Warning
threshold - 2 °C).
To view the device health parameters, click Status and Statistics > Health.
The Health page displays the following fields:
Fan Status—Fan status. The following values are possible:
-
OK—Fan is operating normally.
-
Fail—Fan is not operating correctly.
-
N/A—Fan ID is not applicable for the specific model.
Fan Direction—(On relevant devices) The direction that the fans are working in (for example: Front to
Back).
Temperature—The options are:
-
OK—The temperature is below the warning threshold.
-
Warning—The temperature is between the warning threshold to the critical threshold.
-
Critical—Temperature is above the critical threshold
Diagnostics
See
Administration:

Discovery - Bonjour

See Bonjour.
Cisco Small Business 200 Series Smart Switch Administration Guide
Action
After all the sensors cool down to Warning
Threshold minus 2 degree C, the PHY will be re-
enabled, and all ports brought back up.
If FAN status is OK, the ports are enabled.
(On devices that support PoE) the PoE circuitry is
enabled.
Diagnostics.
6
65

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents