SNMP
Notification Recipients
Informs IPv6 Source Interface—Select the source interface whose IPv4 address will be used as the
source IPv4 address in inform messages for communication with IPv4 SNMP servers.
Traps IPv6 Source Interface—Select the source interface whose IPv6 address will be used as the
source IPv6 address in trap messages for communication with IPv6 SNMP servers.
If the Auto option is selected, the system takes the source IP address from the IP address
NOTE
defined on the outgoing interface.
STEP 3
STEP 4
Server Definition—Select whether to specify the remote log server by IP address or name.
IP Version—Select either IPv4 or IPv6.
IPv6 Address Type—Select either Link Local or Global.
-
Link Local—The IPv6 address uniquely identifies hosts on a single network link. A link local
address has a prefix of FE80, is not routable, and can be used for communication only on the local
network. Only one link local address is supported. If a link local address exists on the interface, this
entry replaces the address in the configuration.
-
Global—The IPv6 address is a global Unicast IPV6 type that is visible and reachable from other
networks.
Link Local Interface—If the IPv6 address type is Link Local, select whether it is received through a
VLAN or ISATAP.
Recipient IP Address/Name—Enter the IP address or server name of where the traps are sent.
UDP Port—Enter the UDP port used for notifications on the recipient device.
Notification Type—Select whether to send Traps or Informs. If both are required, two recipients must
be created.
Timeout—Enter the number of seconds the device waits before re-sending informs.
Retries—Enter the number of times that the device resends an inform request.
Community String—Select from the pull-down the community string of the trap manager. Community
String names are generated from those listed in the Community page.
Notification Version—Select the trap SNMP version.
Either SNMPv1 or SNMPv2 may be used as the version of traps, with only a single version enabled at
a time.
Notification Filter—Select to enable filtering the type of SNMP notifications sent to the management
station. The filters are created in the Notification Filter page.
Cisco Small Business 200 Series Smart Switch Administration Guide
Click Add.
Enter the parameters.
24