Sensor (Tray 5 Feed Out) Late Jam - Lexmark X95x Series Service Manual

Hide thumbs Also See for X95x Series:
Table of Contents

Advertisement

Step
Action and questions
Check the connection between
3
the lower engine PCBA and the
tray module controller PCBA.
Are the above components
properly connected?
POR the machine, and perform a
4
print test. Go to
"PRINT TESTS"
on page
3-26.
Does the error continue?

245.03 Sensor (tray 5 feed out) late jam

Step
Action and questions
Check the media path.
1
Is the media path free of any
media fragments?
Check the feed rollers for wear.
2
Is the above component free of
excess wear and damage?
Check the transport rollers for
3
wear.
Is the above component free of
excess wear and damage?
Check the sensor (tray 5 feed
4
out) for proper connection.
Is the above component
properly connected?
Check the HCF feed/lift motor for
5
proper operation.
When performing
motor tests, ensure
that all cover and
door interlock
switches are
overridden.
1. Enter the Diagnostics Menu.
2. Touch MOTOR TESTS.
3. Touch PRINTER MOTOR
TESTS.
4. Touch HCF feed/lift motor
(feed).
5. Touch HCF feed/lift motor
(lift).
Does the above component
operate properly?
Yes
Replace the tray module
controller PCBA.
Go to
"HCF controller card
PCBA removal" on page
4-432.
Go to step 4.
Replace the upper printer engine
PCBA.
Go to
"Upper printer engine
PCBA removal" on page
4-189.
Yes
Go to step 2.
Go to step 3.
Go to step 4.
Clean or replace the sensor (tray
5 feed out). Go to
"HCF sensor
(tray 5 feedout) removal" on
page
4-446.
Go to step 7.
7558-xxx
No
Replace the connections.
Problem resolved
No
Remove any media or media
fragments.
Replace the feed rollers.
Go to
"HCF feed roll assembly
removal" on page
4-434.
Replace the transport rollers.
Go to
"HCF transport roller kit
removal" on page
4-452.
Replace the connection.
Go to step 6.