Sensor (Tray 3 Feed Out) Late Jam; Sensor (Tray 3 Feed Out) Late Jam (80K Interval Exceeded For Feed Rolls); Previous - Lexmark X95x Series Service Manual

Hide thumbs Also See for X95x Series:
Table of Contents

Advertisement

7558-xxx
Step
Action and questions
POR the machine, and perform a
10
print test. Go to
"PRINT TESTS"
on page
3-26.
Does the error continue?

243.06 Sensor (tray 3 feed out) late jam

See
"243.03/243.06 Sensor (tray 3 feed out) late jam" on page

243.56 Sensor (tray 3 feed out) late jam (80K interval exceeded for feed rolls)

Step
Action and questions
Check the media path.
1
Is the media path free of any
media fragments?
Check the pick/feed rollers for
2
wear.
Is the above component free of
excess wear and damage?
Check the transport rollers for
3
wear.
Is the above component free of
excess wear and damage?
Check the sensor (tray 3 feed
4
out) for proper operation.
1. Enter the Diagnostics Menu.
2. Touch SENSOR TESTS.
3. Touch PRINTER SENSOR
TESTS.
4. Touch Sensor (tray 3 feed
out).
Does the display on the
operator panel change every
time the sensing area of the
above sensor is interrupted or
blocked?
Check the sensor (tray 3 feed
5
out) for proper connection.
Is the above component
properly connected?
Service Manual
2-124
Yes
Replace the upper printer engine
PCBA.
Go to
"Upper printer engine
PCBA removal" on page
4-189.
Yes
Go to step 2.
Go to step 3.
Go to step 4.
Go to step 6.
Clean or replace the sensor (tray
3 feed out). Go to
"Sensor (tray
module feedout) removal" on
page
4-276.
No
Problem resolved
2-122.
No
Remove any media or media
fragments.
Replace the pick/feed rollers.
Go to
"Pick roller removal" on
page
4-144.
Replace the transport rollers.
Go to
"Tray module transport
rollers removal" on page
Go to step 5.
Replace the connection.

Previous

Next
Go Back
4-289.