Dc2+Ph Cancel Request - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

17.6 Common Commands
for All Languages
17.6

DC2+PH Cancel Request

Cancel Request
Command
DC2
HEX code
<12>
16
Default value
None
When turning off the power switch
Valid range
Printer operation in progress
Valid range and
term of
Media sensor information acquisition
command
in progress
Error
[Function]
This command cancels print jobs and clears the entire contents of receive buffer.
[Format]
[DC2] PH
[Return data format (normal)]
[ACK]<06>
16
[Return data format (when a command error occurs)]
[NAK]<15>
16
[Supplemental explanation]
1. The response data is returned after the cancel processing ends.
2. After sending the cancel request command, wait for more than 100 ms before sending the next data.
PH
Parameter
<50>
<48>
None
16
16
The command can be received even during the printer
operation.
The command cannot be received while sensor
information is being acquired. ([NAK] return)
The command cannot be received while an error is
occurring. ([NAK] return)
Host
357
DC2+PH
DC2 + PH
ACK/NAK
Printer
Clear receive buffer
Clear number of