12.7 System
12.7

ESC+~ Multiple Cut

Multiple Cut
ESC
Hexadecimal
code
<1B>
16
Initial value
aaaa=1
When the power switch is OFF
Valid range and
Valid range within items
term of
Valid range between items
command
[Function]
Specifies the number of labels to print between each cut
[Format]
<~>aaaa
●Parameter
a [Number of prints before cutting] =
[Coding Example]
<A>
<V>100<H>200<P>2<L>0202<XM>ABC
<Q>4
<~>2
<Z>
2 pcs
[Supplementary Explanation]
1. Valid only for Cutter models.
2. If this command is not specified in Cutter mode, each label will be cut off after printed.
3. In case the parameter "a" is set to 0, no label will be cut.
4. The product of Qty and value of "aaaa" shall not exceed the maximum number "999999".
5. This command <~> shall be put after Qty<Q>. <Q>, in this case, is to specify number of sheets to be cut.
~
Parameter
<7E>
aaaa
16
The set parameter is not maintained.
The set parameter is valid until next valid setting.
The set parameter becomes initial value at the next item
<A>.
Valid Range
:
Cut
Cut
4 pcs
Feed direction