9.16 Barcode
9.16

ESC+BM UPC-A Barcode (With HRI)

UPC-A Barcode
(With HRI)
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Set the character barcode height of the first and the last digit to the same height of the guard bar.
[Format 1]
<BM>abbcccn~n
●Parameter
a [barcode type]
b [Narrow bar]
c [Height of Barcode]
n [Print data]
[Coding Example]
Barcode type:UPC-A, Narrow bar width:02, Barcode height :120, Print data: 20123948573
<A>
<H>100<V>100<BM>H0212020123948573
<Q>2
<Z>
[Supplementary Explanation]
1. This command supports UPC-A only. When barcode type is specified other than "H", command error occurs.
2. HRI needs following conditions;
8dots /mm (203dpi)
12dots/mm (305dpi)
24dots/mm (609dpi)
When the value other than above is specified, HRI is not printed.
3. Setting of Guard bar, HRI and Ratio is following.
Guard bar
Available
4. When the parameter value exceeds the range, operation is not supported.
5. All character barcode have the same height when printing UPC-A specifying <D> and then <font>. The first and the
last character barcode have the same height to the guard bar when printing UPC-A specifying <BL> and then
<font>.
When printing UPC-A specifying <D> and <font>, HRI can be printed under the first digit and the last digit because
the height of the first digit and the last digit of the barcode is low. When printing UPC-A specifying <BL> and <font>,
the height of the first digit and the last digit of the barcode is high, and the font interval is narrower than previous
case.
Guard bar
Character barcode
First digit
UPC-A specifying <BD>
BM
Parameter
<42>
<4D>
abbcccn~n
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
=
H
: UPC-A( fixed 'H')
=
Valid Range
: 01~36 dots
=
Valid Range
: 001~999 dots
=
Data
: fixed 11 digits
: Set Narrow bar width to [02] or [03]
: Set Narrow bar width to [03] or [04]
: Set Narrow bar width to [06] or [07]or [08]
HRI
Ratio
Available
Fix
Guard bar
Character barcode
Last digit
153
ESC+BM
Guard bar
Character barcode
First digit
UPC-A specifying <BM>
Guard bar
Character barcode
Last digit