Esc+Bl~Esc+D Upc-A Barcode (Without Hri) - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

9.15 Barcode
9.15
ESC+BL~ESC+d
UPC-A Barcode
(Without HRI)
(Without HRl)
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Set the height of character barcode of the first digit and the last digit to the same height of the guard bar.
[Format]
<BL>abbcccn~n~<d>n~n
●Parameter
a [Barcode type]
b [Narrow bar]
c [Height of barcode]
n [Print data]
d [Font type]
n [Print data]
[Coding Example]
Font type: UPC-A, Narrow bar width: 02. Barcode height: 120, Print data: 01234567890
Font type: XS, HRI data: 01234567890
<A>
<H>100<V>100<BL>H0212001234567890
<XS>,01234567890
<Q>2
<Z>
[Supplementary Explanation]
1. This command supports UPC-A only. When barcode type is specified other than "H", command error occurs.
2. Recommended to specify [02] or [03] for the narrow bar width.
3. Check digit (12th digit) for HRI data should be set the calculation result of modulus 10.
4. Setting of Guard bar, HRI and Ratio is following.
Guard bar
Available
5. When the parameter value exceeds the range, operation is not supported.
6. HRI will not be printed when barcode is error for barcode with HRI.
UPC-A
Barcode
BL~d
<42>
<4C>
~character type
16
16
=
H
=
Valid Range
=
Valid range
=
Data
=
OA
OB
XU
XS
XM
XB
XL
U
S
M
WB
WB
=
HRI data
HRI
Ratio
Available
Fix
151
ESC+BL
~ ESC+d
Parameter
abbcccn~n~<d>n~n
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
:
UPC-A (Fixed 'H)
:
01~36 dots
:
001 ~ 999 dots
:
Fixed 11 digit
:
fixed 12 digits