Esc+&R Form Overlay Call - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

14.7 Memory Card
14.7
ESC+&R Form Overlay Call
Form Overlay Call
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Invoking the contents in memory card with Registration of Form Overlay <&S>.
[Format]
<&R>,aa
●Parameter
a [Registration Number]
[Coding Example]
<A>
<CC>1
<&R>,1
<Z>
[Supplementary Explanation]
1. Specify slot number of Card Slot for Use <CC> prior to this command when using.
2. This command can be combined with different registration No. and printed.
3. When registration No. is not specified, this command will be ignored.
4. If specifying unregistered No., Read/Write error will occur.
5. When registering without specifying window, Vertical Print Position <V> and Horizontal Print Position <H> will be
ignored and V1 and H1 (Start position of drawing area) will be determined.
6. When specifying and registering window, movement with <V> and <H> will be enabled.
Note that when exceeding print area, the portion outside of print area will not be printed.
7. The error occurs when specifying unused or specifying the slot which the printer is allocated.
[Note]
Do not turn off the printer while accessing the memory.
[Valid Command]
Print position
<V>
&R
Parameter
<26>
<52>
,aa
16
16
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
=
Valid Range :
1 to 99
<H>