Esc+Ig Sensor Type - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

12.17 System
12.17

ESC+IG Sensor Type

Sensor Type
ESC
Hexadecimal
code
<1B>
16
Initial value
a=1
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifies the sensor type.
[Format]
<IG>a
●Parameter
a [Sensor type]
=
0
1
2
[Coding Example]
<A>
<IG>1
<Z>
[Supplementary Explanation]
1. The setting by this command is normally not needed.
2. The set parameter is maintained after turning off the printer.
3. Do not use this command while printing operation as sensor may not work properly.
4. Receiving print command after changing the sensor type executes printing after backfeed except specifying the
"ignore sensor" to the sensor type.
Feed motion is not performed after turning the printer's power off and then power on.
5. Specifying printer mode to [Tear-off] and [Dispenser], and specifying sensor type to [2] (Ignore sensor) results in
command error.
IG
Parameter
<49>
<47>
a
16
16
The set parameter is maintained.
The set parameter is valid until the next valid setting.
The set parameter is valid until the next valid setting.
Reflective (I-mark)
Transmissible (Gap)
Sensor disabled
257
ESC+IG

Hide quick links:

Advertisement

Table of Contents