Esc+2D32 Micro Qr Code - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

10.6 2D Barcode
10.6

ESC+2D32 Micro QR Code

Micro QR Code
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying QR Code (Micro QR Code)
[Format] (Setup part)
<2D32>,a,bb,c
●Parameter
a [Error Correction Level]
b [Size of one side of cell]
*Specify more than 02 dots when head density is 12dot/mm, otherwise scanner may have reading problem
c [Data setup mode
[Format] (Dat part)
Manual setup (Data setup mode)
<DS>k,n~n
* Use when input mode specification is Numeric mode, Alphanumeric mode and Kanji mode.
<DN>mmmm, n~n
* Use when specifying by binary.
Automatic setup (Data setup mode)
<DN>mmmm, n~n
* Change input mode automatically according to input data.
●Parameter
k [Input mode]
* There is binary specification other than above, but data specification command is different.
m[Number of data」
* Specify when specifying Automatic setup in Data setting mode.
n [Print data]
pp [Version]
[Format] (version)
<QV>pp
* Specify when specifying the version.
●Parameter
pp [Version]
=
* This setting is used when fixing the size of QR symbol with the version command. When not specified, it becomes
Auto.
Specifying 00 also becomes Auto. It doesn't become a parameter error from 00 to 40.
* See [QR code version command] for details.
[Supplementary Explanation1]
1. When specifying Kanji in <DN>, specify size that is 2 X number of Kanji characters.
2. For <DN> in Automatic setup, when 80H to 9FH and E0H to FFH are specified as data, it is handed as Kanji
mode, and cannot specify them as binary.
[Coding Example1] Error correction level :7%, Size of one side of cell:04
<A>
<V>100<H>200<2D32>,L,04
<DS>1,012345
<Q>2
<Z>
[Supplementary Explanation2]
1. If the parameter other than the description is specified or number of print data is not match, print is not executed.
2. Data specification command in data part varies according to parameter setup or specified data.
2D32
<32>
<44>
<33>
<32>
16
16
16
16
=
L
:
7%
M
:
15%
Q
:
25%
=
Valid Range
:
=
0
:
Manual setup
1
:
Automatic setup
=
1
:
Numeric mode
2
:
Alphanumeric mode
3
:
Kanji mode (Shift JIS Kanji)
=
Valid Range : 1 to 15
=
Data
=
00 to 04 (MicroQR M1 to M4)
00 to 04 (MicroQR M1 to M4)
171
ESC+2D32
Parameter
,a,bb,c
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
01 to 99 dots

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents