Esc+Yr Format Call - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

14.10 Memory Card
14.10

ESC+YR Format Call

Format Call
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Invoking and printing out the format registered with Registration of Format <YS>.
[Format]
<YR>,aaa
●Parameter
a [Format registration Number]
[Coding Example]
<A>
<CC>1
<YR>,1
</D>,1,DEF
</D>,2,78901
</D>,3,49000238
<Q>2
<Z>
[Supplementary Explanation]
1. This command cannot invoke multiple formats between Start of Data Transmission <A> and End of Data
Transmission <Z>.
2. Use this command and Print of Field </D> as a pair.
3. The error occurs when specifying unused or specifying the slot which the printer is allocated.
[Note]
Do not turn off the printer while accessing the memory.
YR
Parameter
<59>
<52>
,aaa
16
16
The set parameter is not maintained.
The set parameter is valid until the next valid setting.
The set parameter is valid until the next valid setting.
=
Valid Range
:
283
ESC+YR
1 to 999

Hide quick links: