Esc+Tu Uid Print - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

16.5 RFID
16.5

ESC+TU UID Print

UID Print
Command
ESC
HEX code
<1B>
16
Default Value
Nil
When turning off the power switch
Valid range and
Valid range within item
term of
command
Valid range between items
[Function]
Reads data from RFID tag and develops to specified direction to make it possible to print on label.
[Format]
<TU>a (,bbcccdddn~n)
●Parameters
a
= To use this functionality or not
1: Read data and start using
0: Cancel use
bb = Block number
01: EPC area
02: TID area
03: USER area
ccc = Start address of memory
ddd = End address of memory
The amount of information per one address is 2 bytes (4 characters) in case of Gen2.
An RFID tag error occurs if you specify an address that exceeds tag capacity.
The difference between "Start address of memory" and "End address of memory" shall be kept within 7 because the
maximum amount of read data is 32 characters.
n
= Specify ID. Specify any string within 4 to 16 characters to be used for assigning data.
(All parameters should be in the ASCII format)
TU
Parameter
<54>
<55>
a (,bb,ccc,ddd, n~n)
16
16
The set command is not maintained.
The set parameter is in effect until a new specification is
made.
The set parameter becomes invalid.