Esc+Gi Registration Of Graphic - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

14.12 Memory Card
14.12

ESC+GI Registration of Graphic

Registration of Graphic
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within items
command
Valid range between items
[Function]
Specifying the registration of graphic pattern data.
[Format]
<GI>abbbcccdddn~n
●Parameter
a [Selection of data transfer in HEX or BIN]
Hex data (Divide 8 bits data into 4 bits and outputs it as hex code corresponding to ASCII)
Binary data (Output 8 bits data as one character data all at once)
b [Specification of crosswise graphic area per byte]
c [Specification of lengthwise graphic area per byte]
d [Registration number] (Identification number when invoking) =
n [Data]
[Coding Example 1] [H: HEX data] is specified for [Data specification by HEX and BIN]
[□] is registered to the 999th of the slot 1 by the below.
<A>
<CC>1
<GI>H001001999<46463831383138313831383138314646>
<Z>
[Coding Example 2] [B: Binary data] is specified as Data specification by HEX and BIN]
[□] is registered to the 999th of the slot 1 by the below.
<A>
<CC>1
<GI>B001001999<FF818181818181FF>
<Z>
[Supplementary Explanation]
1. Specify the card slot number used for Card Slot <CC> prior to this command.
2. Specify registered data only.
3. To change the registered content, clear it with Clear <*>
4. Graphic Call <GR> is for printing out the data registered with Registration of Graphic <GI>.
5. When data is not registered properly, print error may occur. For details of data format, refer to Print of Graphic <G>.
6. Attempts to re-register with registered No., error will occur, and the targeted content will be printed.
7. The error occurs when specifying unused or specifying the slot which the printer is allocated.
[Note]
Don't power off while accessing the memory.
[Specified Range]
Head density
8dots/mm
(203dpi)
12dots/mm
(305dpi)
24dots/mm
(609dpi)
GI
Parameter
<47>
<49>
abbbcccdddn~n
16
16
16
Maximum byte in horizontal
direction
104
156
312
285
ESC+GI
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
=
H
:
Hex data
B
:
Binary data
=
Refer to the table below
=
Refer to the table below
Valid range: 1 to 999
=
Graphic data
16
to re-register.
Maximum byte in vertical
direction
400
600
999

Hide quick links: