Dc2+Pi Application Change - SATO CL4NX Programming Reference Manual

Hide thumbs Also See for CL4NX:
Table of Contents

Advertisement

17.7 Common Commands
for All Languages
17.7

DC2+PI Application Change

Application Change
Command
DC2
HEX code
<12>
16
Default Value
None
When turning off the power switch
Valid range
Printer operation in progress
Valid range and
Media sensor information acquisition
term of
in progress
command
Error
Others
[Function]
This command is used to switch applications such as SBPL and SZPL.
[Format]
DC2 (12H) + PI,aa
[Parameters]
Symbol
Parameter name
Identifier
aa
[Return data format (normal)]
[ACK]<06>
16
[Return data format (when a command error occurs)]
[NAK]<15>
16
[Exception processing]
Parameter name
Identifier
Terminology
Command error
Invalid receive data
PI
<50>
<49>
16
16
Valid range
00:AUTO
SB: SBPL
SZ: SZPL
SI: SIPL
SD: SDPL
ST: STPL
Exception condition
A value outside the range is
specified
Command error
Description
The data received after a command error is determined is not
considered as a parameter of this command.
The data corresponding to Byte 2 and thereafter of the identifier is
ignored.
Parameter
,aa
The command cannot be received during the printer
operation. ([NAK] return)
The command cannot be received while sensor
information is being acquired. ([NAK] return)
The command cannot be received while an error is
occurring. ([NAK] return)
Commands cannot be received other than when the
screen is Online or Offline. ([NAK] return.)
Acquisition method
Two characters fixed acquisition
The specified size and received
size are different
Invalid receive data
358
DC2+PI

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents