10.5 2D Barcode
10.5

ESC+2D31 QR Code (Model 1)

QR Code (Model 1)
ESC
Hexadecimal
code
<1B>
16
Initial value
Nil
When the power switch is OFF
Valid range and
term of
Valid range within item
command
Valid range between items
[Function]
Specifying QR Code (Model 1)
[Format] (Setup part)
<2D31>,a, bb, c, d(,ee, ff, gg)
●Parameter
a [Error Correction Level]
b [Size of one side of cell]
* Specify more than 02 dots when head density is 12dot/mm, otherwise scanner may have reading problem
c [Data setup mode
* Note: You need to change the method of specifying print data with this setting.
d [Concatenation mode]
Following parameter must be specified when specifying 1 (Concatenation mode) in Concatenation mode.
Omit following parameter in normal mode.
e [Number of partitions of concatenation mode]
* Number of partitions: Specifying how many QR code are to be concatenated divided by Concatenation mode.
f [Sequential number partitioned by concatenation mode]
* Sequential number: Specifying what number is it of divided QR code.
g [Concatenation mode parity data] =
* Parity data: Specifying exclusive OR of all the print data in divided QR code with HEX characters.
[Format] (Data part)
Manual setup (Data setup mod)
<DS>k,n~n
* Use when input mode specification is Numeric mode, Alphanumeric mode and Kanji mode.
<DN>mmmm, n~n
* Use when specifying by binary.
Automatic setup (Data setup mode)
<DN>mmmm, n~n
* Change input mode automatically according to input data.
●Parameter
k [Input mode]
* Specify only when specifying Manual setup in Data setting mode.
* There is binary specification other than above, but data specification command is different.
m[Number of data]
* Specify when specifying Automatic setup in Data setting mode or specifying binary specification in Manual setup.
n [Print data]
[Format] (version)
<QV>pp
* Specify when specifying the version.
●Parameter
pp [Version]
* This setting is used when fixing the size of QR symbol with the version command. When not specified, it becomes Auto.
Specifying 00 also becomes Auto. It doesn't become a parameter error from 00 to 40.
* See [QR code version command] for details.
2D31
<32>
<44>
<33>
<31>
16
16
16
16
=
L
:
7%
M
:
15%
Q
:
25%
H
:
30%
=
Valid Range
=
0
:
Manual setup
1
:
Automatic setup
=
0
:
Normal mode
1
:
Concatenation mode
Valid Range
=
1
:
Numeric mode
2
:
Alphanumeric mode
3
:
Kanji mode (Shift JIS Kanji)
=
Valid Range
=
Data
= 00 to 14 (MODEL1)
168
ESC+2D31
Parameter
,a,bb,c,d(,ee,ff,gg)
The set parameter is not maintained.
The set parameter becomes invalid.
The set parameter becomes invalid.
:
01 to 99 dots
=
Valid Range
:
=
Valid Range
:
:
00 to FF
:
1 to 486
01 to 16
01 to 16