3.6.2 SOFT SWITCH

(1) Use
• To set the operating characteristic of each function from software switch depending on what types of printing are normally made.
(2) Procedure
1.
Call [SERVICE MODE] to the display.
2. Touch [SYSTEM 2] -> [SOFT SWITCH].
3. Select the Change switch by using the up key/down key, and press the Menu/Select key.
4. Change the bit number by using the up key/down key, and press the Menu/Select key.
(3) Details of the software switch settings
NOTE
• For switches not mentioned in the list below, use them in the default value unless indicated otherwise.
Switch No.
11
Settings for displaying the
life of a imaging unit
059
Display setting of
[ENGINE DIPSW]
120
Change data format of
scanned file names
145
Operation upon mismatch
in size during paper
feeding

3.6.3 MEDIA ADJUSTMENT - FIRST SIDE/SECOND SIDE

(1) Use
• Adjust the 2nd image transfer output (ATVC) on the 1st page and the 2nd page for each paper type.
• To use when the transfer failure at the trailing edge occurs.
(2) Default setting
• Proper value
(3) Setting range
• -8 to +7 (step: 1 *)
*: The 2nd image transfer voltage changes by 5% per 1 step.
(4) Procedure
1.
Call [SERVICE MODE] to the display.
2. Select [SYSTEM 2] -> [MEDIA ADJUSTMENT].
3. Select the side of the image (the 1st side or the 2nd side) on which image transfer failure occurs.
4. Select the paper type with the transfer failure.
Function
Setting value
0
32
0
1
0
1
0
2
I ADJUSTMENT/SETTING > 3. SERVICE MODE
Details
Displays message to the
life of the imaging unit
when the utilization rate
reaches 100%.
Displays message to the
life of the imaging unit
when the utilization rate
reaches 162%.
*: If the setting value is
changed to 32, be sure to
change setting of
IU
YIELD SETTINGS
to "
EXTENSION".
Not displayed.
Displayed.
YYMMDDhhmm(conventi
onal specifications).
Format compatible with
the marketing destination
Stop immediately (jam).
Stop as necessary (stop
after the paper has been
discharged).
I-17