500-Sheet Drawer (2Tm)-Sensor (Media Level) Removal - Lexmark X850e Service Manual

Hide thumbs Also See for X850e:
Table of Contents

Advertisement

2X 500-sheet drawer (2TM)—sensor (media level) removal
1.
Remove the media feed unit assembly. See
removal (tray 3)" on page 4-9
(tray 4)" on page
2.
Disconnect the connector from the sensor (media level) (A).
3.
Release the hooks securing the sensor (media level) (A) to the media feed unit assembly.
4.
Remove the sensor (media level) (A).
"2X 500-sheet drawer (2TM)–media feed unit assembly removal
or
4-11.
Harness
Hooks
Lower view
"2X 500-sheet drawer (2TM)–media feed unit assembly
Front
A
7500-XXX
4-23