Pair Control Solenoid Valve - Suzuki VZ800 Service Manual

Hide thumbs Also See for VZ800:
Table of Contents

Advertisement

11-6 EMISSION CONTROL INFORMATION

PAIR CONTROL SOLENOID VALVE

• Remove the PAIR control solenoid valve. (3-5)
• Check that air flows through the air inlet port to the air outlet
port.
• If air does not flow out, replace the PAIR control solenoid
valve with a new one.
• Connect the 12 V battery to the PAIR control solenoid valve
terminals and check the air flow.
• If air does not flow out, the solenoid valve is in normal condi-
tion.
• Check the resistance between the terminals of the PAIR con-
trol solenoid valve.
 Resistance: 20 – 24 Ω at 20 – 30 °C (68 – 86 °F)
 09900-25008: Multi-circuit tester set
 Tester knob indication: Resistance (Ω)
If the resistance is not within the standard range, replace the
PAIR control solenoid valve with a new one.
Installation is in the reverse order of removal.
• Connect the PAIR control solenoid valve lead wire coupler
and PAIR hoses securely.
• PAIR system hose routing. (11-7)