10-2 SERVICING INFORMATION
TROUBLESHOOTING
FI SYSTEM MALFUNCTION CODE AND DEFECTIVE CONDITION
DETECTED
DTC No.
C00
NO FAULT
CKP sensor
C12
P0335
IAP sensor
C13/C17
P1750/P0105
TP sensor
C14
H
P0120
L
ECT sensor
C15
H
P0115
L
DETECTED FAILURE CONDITION
ITEM
The signal does not reach ECM for 3
sec. or more, after receiving the starter
signal.
The sensor should produce following
voltage.
0.1 V
sensor voltage < 4.8 V
In other than the above range, C13
(P1750) or C17 (P0105) is indicated.
The sensor should produce following
voltage.
0.1 V
sensor voltage < 4.8 V
In other than the above range, C14
(P0120) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
The sensor voltage should be the fol-
lowing.
0.1 V
sensor voltage < 4.6 V
In other than the above range, C15
(P0115) is indicated.
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified
value.
–––––––––––
CHECK FOR
–––––––––––
CKP sensor wiring and mechan-
ical parts
(CKP sensor, lead wire/coupler
connection)
IAP sensor, lead wire/coupler
connection
TP sensor, lead wire/coupler
connection
TP sensor circuit shorted to
VCC or ground circuit open
TP sensor circuit open or
shorted to ground or VCC circuit
open
ECT sensor, lead wire/coupler
connection
ECT sensor circuit open or
ground circuit open
ECT sensor circuit shorted to
ground