Emitter Pulse Duty Ratio For Sensors Il1, Il2, And Il3 - Kodak Ektascan 1120 Service Manual

Hide thumbs Also See for Ektascan 1120:
Table of Contents

Advertisement

SERVICE MANUAL

Emitter Pulse Duty Ratio for Sensors IL1, IL2, and IL3

Duty Cycle Ratio is defined as percent of time the SENSORS are on divided by the percent of time the SENSORS
are off.
Lower the Duty Cycle Ratio if film fogging has occurred. Adjusting the 3 SWITCHES changes the ratio of emitter
time per cycle. The Duty Ratio may need to be changed when non-Kodak films are used.
Note
The switches RSW1 and RSW2 on the DRIVER BOARD are factory-set to 8 for a Duty Ratio of 60%. RSW3 is
factory set to 3 for a Duty Ration of 28 percent.
PHT2, IL1 - RSW2: for the SLOW SCAN FILM SENSOR
PHT3, IL2 - RSW3: for the FILM PROCESSOR ADAPTER SENSOR
PHT1, IL3 - RSW1: for the TRANSPORT GUIDE PLATE FILM JAM SENSOR
Note
If changing the Duty Ratio, select one of the following switch settings to select the percent shown:
Switch Setting
* Not recommended.
5–38
Duty Ratio
*0
9.4%
*1
16%
2
22%
3
28%
4
34%
5
41%
6
47%
7
53%
Switch Setting
Duty Ratio
8
60%
9
66%
*A
72%
*B
78%
*C
84%
*D
91%
*E
97%
*F
100%
10FEB97 – SM3226-1

Advertisement

Table of Contents
loading

Table of Contents