The following is a list of parameters in the sequence in which they are displayed:
Parameter
"BS PULSE xx:yyy:
"FILM SIZE: xxxxx"
"FILM OUTPUT: xxxxx" To set the film output.
"MAX RECEIVE: xxx"
"R-MAG FILM: xxx"
"FST: xx.xxmm"
"IMST (8x10): xx.xxmm" To set the 8x10 image start position.
"IMST: xx.xxmm"
"PEST: xxx.xxmm"
"PEEND: xxx.xxmm"
"SLOW: xx.xxmm"
"PRINT COUNT: xxx"
"JAM ERROR: xx"
"ACTIVE CAL: X"
"DENSITY: xx"
"RAW DATA x:y_yy"
"CAL DATA: xxxx"
"CONTRAST: xx"
"LOW STEP: xxx"
"USER CAL: xxxxxxx"
"TRANSPORT:
NORMAL/SPECIAL"
"PROC TYPE:"
*
If using 8 x 10 in. FILM, select "80" for the maximum receive value. If using 35 x 43 cm.
select either "80" or "100", depending on the particular needs of the customer.
**
Do not enter new values for Raw Data after Calibration has been completed.
***
Changing "TRANSPORT" from "NORMAL" to "SPECIAL" will correct vertical banding
artifacts.
**** Used only on new PRINTERS, or old PRINTERS that have had Modification 6 installed.
SM3226-1 – 10FEB97
Description
To set the beam splitter pulses from 0 to
200.
To set the film size.
To set the maximum number of film
sheets for the Receive Magazine.
To read the number of film sheets in the
Receive Magazine.
To set the film start position.
To set an image start position other than
8x10.
To set the Polygon edge start position.
To set the Polygon edge end position.
To set the Slow Scan direction position.
To set the number of test prints.
To store the jam error.
To set the density. (-3 to +3)
To enter data for calibration
To use the previously entered raw data to
calibrate the PRINTER when calibration
error occurs. See the procedure on Page
4–12 for more information.
To set the contrast for test prints.
To set the number of pulses for the "Film
Supply Low" message. (162 - 222)
To set the permission/inhibition for
calibration.
To correct vertical banding.
To choose the PROCESSOR that is
docked to the PRINTER.
Operation Adjustments
Enter this value:
See LABEL for values.
35x43/35x35/14x11/8x10
Proc/R-Mag
80/100 *
0
See LABEL for values.
1
0
1-11
0
(1)0.15, (2)0.22, (3)0.42,
(4)0.79, (5)1.25, (6)1.73,
(7)2.12, (8)2.46, (9)2.71 **
OK
0
Enter desired value, See
label, default=192
PERMIT
NORMAL ***
Choose "M35/270RA" or
"M7B". ****
4–23