FIP1.2 ROS Error
Step
Possible causes:
ROS ASSY (PL8.1.1)
HVPS/MCU (PL12.1.19)
EP CARTRIDGE
HARNESS ASSY ROS (PL8.1.2)
LVPS (PL12.1.5)
Checking NVRAM for data setup value.
Are the values of NV03 (resolution) and the value of
NV04 (Laser Diode output) set at the initial setup value
1
in the factory?
Check using Chapter 2 Diagnostic [ADJUSTMENT
PARAMETER INITIALIZE MODE].
Check
1 – 12
Chapter 1 Troubleshooting
Yes
Set NV03 and
NV04 to factory
setup, and then
Go to FIP1.26
check again. If
ROS ASSY.
Error still occurs,
go to FIP1.26 ROS
No
ASSY.