Fip1.16 Drum Life - Oki B6500 Service Manual

Hide thumbs Also See for B6500:
Table of Contents

Advertisement

FIP1.16 Drum Life

Step
Possible causes:
EP CARTRIDGE
GUIDE ASSY CRU R (PL8.1.25)
HVPS/MCU (PL12.1.19)
Checking EP CARTRIDGE
1
Does Error still occur, after installing a new EP CAR-
TRIDGE?
Checking GUIDE ASSY CRU R for continuity
Remove EP CARTRIDGE.
2
Remove GUIDE ASSY CRU R. (RRP8.13)
Is each cable of each harness continuous?
Check
1 – 31
Chapter 1 Troubleshooting
Yes
Go to step 2.
End of work
Replace HVPS/
Replace GUIDE
MCU.
ASSY CRU R.
(RRP12.10)
(RRP8.13)
No

Advertisement