Fip3.14 Sensor Full Stack (On Pwba Oct) - Oki B6500 Service Manual

Hide thumbs Also See for B6500:
Table of Contents

Advertisement

FIP3.14 Sensor Full Stack (On PWBA OCT)

Step
Possible causes:
Sensor Full Stack (Mounted on PWBA OCT)
ACTUATOR FULL STACK (PL23.1.15)
PWBA OCT (PL23.1.22)
HARNESS ASSY OCT2 (PL23.1.25)
HVPS/MCU (PL12.1.19)
HARNESS ASSY OCT1 (PL12.1.26)
Checking ACTUATOR FULL STACK for operation
Remove Option OCT. (RRP23.1)
Move ACTUATOR FULL STACK with a finger.
1
Does ACTUATOR FULL STACK operate smoothly?
Does the flag go into the sensor detecting point when
there is no paper, and out of the detecting point when
the paper is set?
Checking Sensor Full Stack mounted on PWBA OCT
(1)
Remove EP CARTRIDGE.
Install Option OCT. (RRP23.1)
2
Move ACTUATOR FULL STACK up and down.
Does the number increase one by one, every time
ACTUATOR FULL STACK operates?
Check using Chapter 2 Diagnostic [Sensor/Switch
Check].
Checking HARNESS ASSY OCT2 for continuity
Disconnect P/J70 from PWBA OCT.
3
Remove HARNESS ASSY OCT2.
Is there continuity between J70 and J3070?
Checking HARNESS ASSY OCT1 for continuity
4
Remove HARNESS ASSY OCT1.
Is there continuity between J30 and J3070?
Checking Sensor Full Stack mounted on PWBA OCT
(2)
5
Replace PWBA OCT. (RRP23.7)
Is the problem cleared?
Check
1 – 95
Chapter 1 Troubleshooting
Yes
With tool Go to
Replace ACTUA-
step 2. Without
TOR FULL STACK.
tool Go to step 3.
Replace HVPS/
MCU.
Go to step 3.
(RRP12.10)
Replace HAR-
Go to step 4.
NESS ASSY
Replace HAR-
Go to step 5.
NESS ASSY
Replace HVPS/
End of work
MCU. (RRP12.10)
No
OCT2.
OCT1.

Advertisement

Table of Contents
loading

Table of Contents