After tightening the screws, move the GUIDE ASSEMBLY END 150 back and forth, and
make sure that the LINK SW SIZEs operate smoothly.
6)
While pressing down the hook of the HOUSING TOP 150, install the GUIDE ASSEMBLY SD R150
(PL 2.1) to the HOUSING TOP 150.
After installing, make sure that the 3 claws of the GUIDE ASSEMBLY SD R150 sit cor-
rectly in the grooves of the HOUSING TOP 150. (NOTE 4) (Figure 1).
7)
While pressing down the hook of the HOUSING TOP 150, install the GUIDE ASSEMBLY SD L150
(PL 2.1) to the HOUSING TOP 150.
After installing, make sure that the 3 claws of the GUIDE ASSEMBLY SD L150 sit cor-
rectly in the grooves of the HOUSING TOP 150. (NOTE 4) (Figure 1).
8)
Push the PLATE ASSEMBLY BTM downward to lock.
9)
With completely opened GUIDE ASSEMBLY SD L150 (PL 2.1) and GUIDE ASSEMBLY SD R150
(PL 2.1) to the both sides, install the GEAR PINION (PL 2.1) to the HOUSING TOP 150.
When installing the GEAR PINION, make sure the GUIDE ASSEMBLY SD R150 and
GUIDE ASSEMBLY SD L150 are completely opened. If not, the side register may be mis-
aligned.
10) Install the COVER CST (PL 2.1) to the 150 PAPER CASSETTE.