Replacement
1)
Install the HOLDER LEFT (PL 5.1) and ACTUATOR NO PAPER to the SUPPORT NUDGER (PL
5.1).
Be sure to install the shafts on both ends of the ACTUATOR NO PAPER into the
HOLDER LEFT and SUPPORT NUDGER.
Assemble the hook of the ACTUATOR NO PAPER to the HOLDER LEFT as shown (Fig-
ure
1).
2)
Move the HOLDER LEFT in the opposite direction of the arrow, and secure it to the 550 FEEDER
ASSEMBLY with the 3 hooks (Figure 1).
After installing, move the ACTUATOR NO PAPER with a finger, and make sure that the
ACTUATOR NO PAPER operates smoothly.
3)
Return the printer to the normal use state.
4)
Install the FUSER ASSEMBLY (PL 6.1) (RRP6.8).
5)
Install the COVER REAR 500 (PL 7.1) (RRP7.9).