Rrp9.6 Fan Main (Pl 1.1.14) - Oki B6500 Service Manual

Hide thumbs Also See for B6500:
Table of Contents

Advertisement

RRP9.6
FAN MAIN (PL 1.1.14)
Removal
1)
Remove the COVER REAR 500 (PL 7.1) (RRP7.9).
2)
Remove the COVER REAR (PL 1.1) (RRP1.1).
3)
Release the harness clamps of the FAN MAIN (Figure 1).
4)
Remove the 2 screws (silver tapping,8mm) securing the FAM MAIN to the COVER REAR, and
remove the FAN MAIN (Figure 1).
Replacement
1)
Install the FAN MAIN to the COVER REAR using the 2 screws (silver tapping, 8mm) (Figure 1).
When installing, be sure to install the FAN MAIN so that the label is facing outside.
When installing, make sure the harness is not pinched between the FAN MAIN and the
COVER REAR.
2)
Attach the harness of the FAN MAIN with the clamp (Figure 1).
3)
Install the COVER REAR (PL 1.1) (RRP1.1).
There are 2 kinds of screws, make sure they are installed correctly.
4)
Install the COVER REAR 500 (PL 7.1) (RRP7.9).
Chapter 3 Removal and Replacement Procedures (RRPs)
Figure 1. Main Fan
3 - 156