Table 73. Pef Action Priorities; Table 74. Mbmc Factory Default Event Filters - Intel SE7520AF2 Technical Product Specification

Hide thumbs Also See for SE7520AF2:
Table of Contents

Advertisement

Intel® Server Board SE7520AF2 TPS
Diagnostic Interrupt
Alert
The mBMC maintains an Event Filter table with 30 entries that is used to select the actions to
perform. Also maintained is a fixed/read-only Alert Policy Table entry. No alert strings are
supported.
Note: All Fault/Status LED and ID LED behaviors are driven off of PEF. PEF should not be
disabled and the manufacturing shipping configuration should not be modified or those
behaviors will be changed.
Each time the PEF module receives either an externally or internally generated event message,
it compares the event data against the entries in the event filter table. The mBMC scans all
entries in the table and determines a set of actions to be performed. If a combination of actions
is identified, such as power down, power cycle, and/or reset actions, the action are performed
according to PEF Action Priorities. Action priorities are outlined in the table below.
Note: An action that has changed from delayed to non-delayed, or an action whose delay time
has been reduced has a higher priority. Each generated event is logged by SEL.
Action
Power-down
Soft shut-down
Power cycle
Reset
Diagnostic Interrupt (NMI)
PET Alert
IPMB message event
Event Filter #
1
Non-critical
2
Non-critical
3
Critical
4
Critical
5
Critical
6
Critical
7
Critical
Revision 1.2

Table 73. PEF Action Priorities

Priority
Delayed
1
Yes
PEF Action
2
Yes
OEM PEF Action
3
Yes
PEF Action
4
Yes
PEF Action
5
No
PEF Action
6
No
PEF Action
8
No
OEM PEF Action

Table 74. mBMC Factory Default Event Filters

Offset Mask
Intel order number C77866-003
Type
Not executed if a power-down action was
also selected.
Not executed if a power-down action was
also selected.
Not executed if a power-down action was
also selected.
Not executed if a power-down action was
also selected.
When selected, always occurs immediately
after detection of a critical event.
When selected, always occurs immediately
after detection of a critical event.
Voltage Assert
Voltage Deassert
Voltage Assert
Voltage Deassert
PS Soft Fail Assert
PS Soft Fail Deassert
Proc 1-2 Thermal Trip Assert
Platform Management
Note
Events