Lan Alerting; Table 20. Factory Configured Pef Table Entries - Intel S1200V3RP Technical Product Specification

Hide thumbs Also See for S1200V3RP:
Table of Contents

Advertisement

Intel® Server Board S1200V3RP TPS
Event Filter
Number
1
2
3
4
5
6
7
8
9
10
11
12
Additionally, the BMC supports the following PEF actions:
Power off
Power cycle
Reset
OEM action
Alerts
The Diagnostic interrupt action is not supported.
6.11.10

LAN Alerting

The BMC supports sending embedded LAN alerts, called SNMP PET (Platform Event traps),
and SMTP email alerts.
The BMC supports a minimum of four LAN alert destinations.
6.11.10.1
SNMP Platform Event Traps (PETs)
This feature enables a target system to send SNMP traps to a designated IP address by means
of LAN. These alerts are formatted per the Intelligent Platform Management Interface
Specification Second Generation v2.0. A Modular Information Block (MIB) file associated with
the traps is provided with the BMC firmware to facilitate interpretation of the traps by external
software. The format of the MIB file is covered under RFC 2578.
Revision 1.2

Table 20. Factory Configured PEF Table Entries

Offset Mask
Non-critical, critical and non-
recoverable
Non-critical, critical and non-
recoverable
Non-critical, critical and non-
recoverable
General chassis intrusion
Failure and predictive failure
Uncorrectable ECC
POST error
FRB2
Policy Correction Time
Power down, power cycle, and
reset
OEM system boot event
Drive Failure, Predicted Failure
Platform Management Functional Overview
Events
Temperature sensor out of range
Voltage sensor out of range
Fan failure
Chassis intrusion (security
violation)
Power supply failure
BIOS
BIOS: POST code error
Watchdog Timer expiration for
FRB2
Node Manager
Watchdog timer
System restart (reboot)
Hot Swap Controller
61

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents