Configuration the Switch Blade Module
Figure 4-1. Installation and Configuration Flow

5.4 Configuring the Terminal

To configure the device, the station must be running terminal emulation software. Ensure that
switch module is correctly mounted and is connected to the chassis serial port. Ensure that the
terminal emulation software is set as follows: Connect PRIMERGY BX Blade Server serial port
to the Ethernet Switch Module.
NOTE:
1. The default data rate is 115200. No other data rate is required for initial configuration.
2. Sets the data format to 115200 baudrate 115200,8 data bits, 1 stop bit, and no parity.
3. Sets Flow Control to none.
4. Under Properties, select VT100 for Emulation mode.
5. Select Terminal keys for Function, Arrow, and Ctrl keys. Ensure that the setting is for
Terminal keys (not Windows keys).
For accessing switch module from terminal perform following steps: