4.5.4 2ND BTR ASSY

REMOVAL
1.
Open COVER ASSY TOP.
2.
Remove Photoconductor Unit.
When performing the following work, press LATCH ROTARY on
C A U T I O N
LATCH ASSY ROTARY to release the latch, turn FRAME ASSY-
ROTARY by hand, and move HOUSING ASSY-DEVE to prevent
it from contacting MAG ROLL.
3.
Turn the levers on both the left and right sides of 2ND BTR ASSY towards you,
and unlock the lever lock from FRAME ASSY-2ND.
4.
Hold the lever on 2ND BTR ASSY, draw out the right side of 2ND BTR ASSY
from FRAME ASSY-2ND, and then draw out the left side to remove 2ND BTR
ASSY from the main unit.
DISASSEMBLY AND ASSEMBLY
3)
4)-2
Figure 4-63. Removal of 2ND BTR ASSY
TRANSFER
CAUTION
3)
4)-3
4)-1
Leg_Sec03_070EA