4.5.9 SENSOR 2BTR RETRACT

REMOVAL
1.
Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND.
2.
Disconnect connector (P/J112) from SENSOR 2BTR RETRACT.
3.
Remove the screw (silver, with flange, 8 mm) fastening BRACKET-SENSOR
PHOTO to the main unit.
4.
Remove BRACKET-SENSOR PHOTO from the main unit together with
SENSOR 2BTR RETRACT.
5.
Unhook the three hooks fastening SENSOR 2BTR RETRACT to BRACKET-
SENSOR PHOTO, and remove SENSOR 2BTR RETRACT.
REINSTALLATION
1.
Match the hooks on SENSOR 2BTR RETRACT with the attachment position, and
attach to BRACKET-SENSOR PHOTO.
2.
Match the hole on BRACKET-SENSOR PHOTO with the boss on the main unit,
and attach BRACKET-SENSOR PHOTO together with SENSOR 2BTR
RETRACT.
3.
Fasten BRACKET-SENSOR PHOTO to the main unit with the screw (silver, with
flange, 8mm).
4.
Connect connector (P/J112) to SENSOR 2BTR RETRACT.
The shutter of CAM ASSY-2ND must be inserted inside the sensor
C A U T I O N
on SENSOR 2BTR RETRACT.
5.
Attach CHUTE ASSY-FSR and COVER ASSY-RR 2ND.
DISASSEMBLY AND ASSEMBLY
(p.341)
(p.341)
TRANSFER
CAUTION
Figure 4-68. Removal of SENSOR 2BTR RETRACT