EPSON AcuLaser C1100

4.10.3 MOT ASSY FSR

REMOVAL
1.
Remove COVER ASSY LH.
(p.295)
2.
Disconnect connector (P/J404) from the PWBA MCU.
3.
Unclamp the clamp fastening the harness on MOT ASSY FSR and remove the
harness.
4.
Remove the 2 screws (silver, with flange, 4mm) fastening MOT ASSY FSR to the
main unit.
5.
Remove MOT ASSY FSR from the main unit.
REINSTALLATION
1.
Attach MOT ASSY FSR to the main unit.
2.
Fasten MOT ASSY FSR to the main unit with the 2 screws (silver, with flange,
4mm).
3.
Connect the (P/J404) to the PWBA MCU.
4.
Fasten the harness of MOT ASSY FSR with the clamp.
5.
Attach COVER ASSY LH.
(p.295)
Table 4-4. Symptoms when the connector is loose
Connector
Panel Indication
Symptom
No.
Jam C, E, F
Paper Jam at 2nd
P/J404
BTR section
Jam D, F