Epson AcuLaser C1100 Service Manual page 139

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100
FIP-6
Panel Message
Photocondctr Trouble
Possible parts that caused the error
Photoconductor Unit
HARNESS-ASSY XERO
LV/HVPS
Troubleshooting
Step
Check
Model check of Photoconductor Unit
1
Is a Photoconductor Unit that complies with
the specifications attached?
Attachment check of Photoconductor Unit
2
Re-attach Photoconductor Unit.
Does the error recur when the power is turned
ON?
Check after replacement of
3
Photoconductor Unit
Replace Photoconductor Unit.
Does the error recur when the power is turned
ON?
Check of ANTENNA ASSY
4
Is ANTENNA ASSY dirty and damaged?
Does the error recur when the power is
5
turned ON?
TROUBLESHOOTING
GUIDE CRU ASSY D or ANTENNA ASSY
PWBA MCU
Yes
No
Go to Step [2].
Replace with a
Photoconductor
Unit that
complies with
the
specifications.
Go to Step [3].
End of
procedure
Go to Step [4].
End of
procedure
Clean
Go to Step [6].
ANTENNA
ASSY, and then
proceed to step
[5].
Go to Step [6].
End of
procedure
FIP according to the printer message
Step
Check
Continuity check of HARNESS-ASSY XERO
6
Disconnect P/J416 from PWBA MCU.
Do all of the wiring below have normal
continuity.
J416-4 ↔ J109-2
J416-5 ↔ J109-1
Check after replacement of GUIDE CRU
7
ASSY D or ANTENNA ASSY
Replace GUIDE CRU ASSY D or
ANTENNA ASSY.
(p.362)
or
(p.365)
Does the error recur when the power is turned
ON?
Power supply check to PWBA MCU
8
Are the following power voltages being
supplied to PWBA MCU from LV/HVPS?
J410-1 ↔ J410-2: 3. 3 VDC
J410-3 ↔ J410-4: 5 VDC
J410-5/6 ↔ J410-7/8: 24 VDC
Continuity check of HARNESS ASSY MAIN
9
Disconnect P/J410 from PWBA MCU and P/
J502 from LV/HVPS.
Do all of the wiring below have normal
continuity?
J410-1 ↔ J502-1
J410-2 ↔ J502-2
J410-3 ↔ J502-3
J410-4 ↔ J502-4
J410-5 ↔ J502-5
J410-6 ↔ J502-6
J410-7 ↔ J502-7
J410-8 ↔ J502-8
Revision B
Yes
No
Go to Step [7].
Replace
HARNESS-
ASSY XERO.
Go to Step [8].
End of
procedure
Replace PWBA
Go to Step [9].
MCU.
(p.404)
Replace LV/
Repair broken
HVPS.
(p.407)
or shorted part.
139

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents