4.4.5 CLUTCH ASSY REGI

Step numbers with [ ] in the figure indicate the step of
C A U T I O N
reinstallation.
REMOVAL
1.
Remove FRAME ASSY-PH.
(p.327)
2.
Remove MOTOR-PH.
(p.337)
3.
Remove DRIVE ASSY-PH.
(p.340)
When performing the following work, leave the intermediate
C A U T I O N
connector on the harness side.
4.
Disconnect the connector (P/J203) from CLUTCH ASSY REGI, and remove the
harness of CLUTCH ASSY REGI from the groove on FRAME ASSY-PH.
5.
Remove the E-ring fastening CLUTCH ASSY REGI to FRAME ASSY-PH.
6.
Remove CLUTCH ASSY REGI from FRAME ASSY-PH.
REINSTALLATION
1.
Match the hole position of CLUTCH ASSY REGI with the D cut surface on the
shaft of ROLL-REGI METAL, and attach CLUTCH ASSY REGI so that the
protrusion of FRAME ASSY-PH enters the concave portion on CLUTCH ASSY
REGI.
2.
Fasten CLUTCH ASSY REGI to FRAME ASSY-PH with the E-ring.
3.
Route the harness of CLUTCH ASSY REGI in the groove on FRAME ASSY-PH,
and connect the connector (P/J203) to CLUTCH ASSY REGI.
4.
Attach DRIVE ASSY-PH.
(p.340)
5.
Attach MOTOR-PH.
(p.337)
6.
Attach FRAME ASSY-PH.
(p.327)
DISASSEMBLY AND ASSEMBLY
6)
5)
Figure 4-46. Removal of CLUTCH ASSY REGI