4.5.11 PLATE BIAS-2ND ASSY

REMOVAL
1.
Remove COVER ASSY RH.
(p.301)
2.
Remove CHUTE ASSY-FSR and COVER ASSY-RR 2ND.
3.
Remove 2ND BTR ASSY.
(p.348)
4.
Remove the 2 screws (silver, with flange, tapping, 6 mm) fastening PLATE BIAS-
2ND ASSY to the main unit.
When performing the following work, take care not to remove
C A U T I O N
PLATE BIAS-2ND ASSY too far as it is connected by WIRE ASSY
2BTR.
5.
Unclamp the clamp fastening WIRE ASSY 2BTR, and slightly release PLATE
BIAS-2ND ASSY from the main unit.
6.
Remove the screw (silver, tapping, 6 mm) fastening the terminal of WIRE ASSY
2BTR to PLATE BIAS-2ND ASSY.
7.
Remove WIRE ASSY 2BTR from PLATE BIAS-2ND ASSY, and remove
PLATE BIAS-2ND ASSY.
DISASSEMBLY AND ASSEMBLY
4)
(p.341)
5)-2
TRANSFER
E ring
4)
7)
6)
5)-1
Figure 4-70. Removal of PLATE BIAS-2ND ASSY