EPSON AcuLaser C1100
4.12.8 ACTUATOR INV
REMOVAL
1.
Remove DUPLEX ASSY.
(p.412)
2.
Remove COVER-R DUP.
(p.413)
3.
Remove COVER-L DUP.
(p.414)
4.
Remove LINK-LATCH and LINK-BUTTON.
5.
Open COVER UP-DUP TRANS, and remove INVERTER ASSY DUP. Note that
COVER LOW-DUP TRANS and COVER UP-DUP TRANS need not be
removed.
(p.417)
6.
Remove COVER-INV.
(p.415)
7.
Unhook the hook fastening ACTUATOR INV to INVERTER ASSY DUP, and
remove ACTUATOR together with SPRING ACTUATOR.
8.
Remove SPRING ACTUATOR from ACTUATOR INV.
REINSTALLATION
1.
Attach SPRING ACTUATOR to ACTUATOR INV.
2.
After inserting the left-side shaft of ACTUATOR into the hole on INVERTER
ASSY DUP, attach ACTUATOR INV together with SPRING ACTUATOR, and
fasten by the hook.
SPRING ACTUATOR must be firmly hooked onto ACTUATOR
C A U T I O N
INV and DUPLEX ASSY.
3.
Attach COVER-INV.
(p.415)
4.
Attach INVERTER ASSY DUP.
5.
Attach LINK-LATCH and LINK-BUTTON.
6.
Attach COVER-L DUP.
(p.414)
7.
Attach COVER-R DUP.
(p.413)
8.
Attach DUPLEX ASSY.
(p.412)
DISASSEMBLY AND ASSEMBLY
(p.416)
(p.417)
(p.416)
7)-2
Figure 4-123. Removal of ACTUATOR INV
DUPLEX
Revision B
CAUTION
8)
7)-1
Leg_Sec03_123FA
421