EPSON AcuLaser C1100

4.6 XERO

4.6.1 SENSOR TR-0

REMOVAL
1.
Open COVER ASSY TOP.
2.
Remove Photoconductor Unit.
3.
Remove the screw (silver, with flange, 10mm) fastening SENSOR TR-0 to
PLATE-TR-0.
4.
Remove SENSOR TR-0 from PLATE-TR-0.
5.
Disconnect connector (P/J108) from SENSOR TR-0.
REINSTALLATION
1.
Connect connector (P/J108) to SENSOR TR-0.
2.
Match the hole on SENSOR TR-0 with the boss on PLATE-TR-0, and attach
SENSOR TR-0.
3.
Fasten SENSOR TR-0 to PLATE-TR-0 with the screw (silver, with flange,
10mm).
4.
Attach Photoconductor Unit.
5.
Close COVER ASSY TOP.
DISASSEMBLY AND ASSEMBLY
5)
3)
4)
Figure 4-72. Removal of SENSOR TR-0