4.11.8 PWBA FUSER CONT

Avoid staticky places such as on a carpet especially when removing
C A U T I O N
or inserting a Board. Before starting work with the Board, make
sure to touch metallic portion of the printer connected to the earth
to let your body come out free of static electricity.
REMOVAL
1.
Remove COVER ASSY LH.
(p.295)
2.
Remove CHASSIS ASSY ESS.
3.
Disconnect all connectors from the PWBA FUSER CONT.
4.
Remove the 2 screws (silver, with flange, 8mm) fastening PWBA FUSER CONT
to the main unit.
5.
Remove the screw (silver, with external toothed washer, 5 mm) fastening PWBA
FUSER CONT to the main unit.
6.
Remove PWBA FUSER CONT from the main unit.
REINSTALLATION
1.
Match the boss and protrusion on PWBA FUSER CONT with the hole on the main
unit, and attach PWBA FUSER CONT.
2.
Fasten PWBA FUSER CONT to the main unit with the screw (silver, with external
toothed washer, 5 mm).
3.
Fasten PWBA FUSER CONT to the main unit with the 2 screws (silver, with
flange, 8mm).
4.
Connect all connectors to the PWBA FUSER CONT.
5.
Attach CHASSIS ASSY ESS.
(p.411)
6.
Attach COVER ASSY LH.
(p.295)