Sensor Rotary Home Posi - Epson AcuLaser C1100 Service Manual

A4 full color laser printer
Hide thumbs Also See for AcuLaser C1100:
Table of Contents

Advertisement

EPSON AcuLaser C1100

4.8.5 SENSOR ROTARY HOME POSI

REMOVAL
1.
Remove COVER ASSY LH.
(p.295)
2.
Remove LV/HVPS.
(p.407)
3.
Remove the screw (silver, with flange, 6 mm) fastening BRACKET SENSOR to
the main unit.
4.
Remove BRACKET SENSOR from the main unit together with SENSOR
ROTARY HOME POSI.
5.
Disconnect connector (P/J105) from SENSOR ROTARY HOME POSI.
6.
Unhook the three hooks fastening SENSOR ROTARY HOME POSI to
BRACKET SENSOR, and remove SENSOR ROTARY HOME POSI.
REINSTALLATION
1.
Match the hooks on SENSOR ROTARY HOME POSI with the attachment
position, and attach to BRACKET SENSOR.
2.
Connect connector (P/J105) to SENSOR ROTARY HOME POSI.
3.
Match the hole on BRACKET SENSOR with the boss on the main unit, and attach
BRACKET SENSOR together with SENSOR ROTARY HOME POSI.
4.
Fasten BRACKET SENSOR to the main unit with the screw (silver, with flange, 6
mm).
5.
Attach LV/HVPS.
(p.407)
6.
Attach COVER ASSY LH.
(p.295)
DISASSEMBLY AND ASSEMBLY
6)-1
4)
3)
Figure 4-92. Removal of SENSOR ROTARY HOME POSI
DEVE
6)-2
5)
Leg_Sec03_093EB
Revision B
382