● Install the needle valve ①, float ② float arm pin ③.
FLOAT ADJUSTMENT
● To check the float height, invert the carburetor
body, holding the float arm pin so that the pin will
not slip off.
Float height
● Check to be sure that the float moves freely.
● Install the new O-ring ⑤ and float chamber
groove ④.
● Install the float chamber and screw.

ACCELERATOR PUMP ADJUSTMENT

CAUTION
Do not adjust except for exchange the adjust
screw.
● Adjust idling. (Refer to page 2-9)
● Adjust throttle grip. (Refer to page 2-9)
● Adjust clearance of the accelerator pump rod after
loosen the lock nut and turn the adjust screw.
● Tighten the lock nut.
Lock nut clearance
12.5 mm
0 mm
Adjust screw