INSPECTION
MAGNETO
Using the pocket tester, measure the resistance
between the lead wires in the following table.
Pick-up coil
Charging coil
Pocket Tester : 09900-25002
CAUTION
When mounting the stator on the magneto cover,
apply a small quantity of THREAD LOCK "1324"
to the threaded parts of screws.
Thread Lock "1324"
WIRE COLOR
L
: Blue
G
: Green
R
: Red
W
: White
Y
: Yellow
B / R
: Black with Red tracer
L / R
: Blue with Red tracer
R / G
: Red with Green tracer
W / G
: White with Green tracer
W / R
: White with Red tracer
CDI UNIT
Using the pocket (R×1㏀ range), measure the resis-
tance between the lead wires in the following table.
Pocket tester : 09900-25002
G-L Approx 90~110 Ϊ
Y-Y Approx 0.6~0.9 Ϊ