Cleaning the lower roller
housing assembly area
A-61096 June 1999
To clean the lower roller housing assembly area, follow the steps
below:
1. Open the top cover.
2. Open the right-side access door.
Lower roller
housing assembly
3. Grasp the vertical baffle handle, push it in and turn it
counterclockwise until the baffle plate unlatches. Pull the baffle
plate down until it stops, this unlocks the lower roller assembly.
4. Slide the lower roller housing assembly out of its housing and
vacuum inside the housing.
IMPORTANT: Do not slide the lower roller housing assembly back
into place without first removing the imaging guides.
Failure to remove them first can cause misalignment
and/or damage to the machine.
5. Remove the imaging guides (not shown in this illustration).
IMPORTANT: Use care when handling the imaging guides. Hold
the imaging guides by the green handles only .
6. Slide the lower roller housing assembly back into its original
position.
7. Replace the imaging guides.
8. Vacuum the screen located at the base of the transport system.
IMPORTANT: Do not insert the vacuum cleaner nozzle under the
lower roller housing assembly. The lamp sensor
may be damaged or dislodged.
9. Raise the baffle plate and push it into its original position. Turn the
vertical baffle handle and latch it into place.
10. Close the right-side access door and top cover.
Vertical baffle handle
Baffle plate
Lower roller
housing
assembly
Screen
5-13