Adjusting the feed shelf
position
2-14
11. When you have adjusted the gap so the bottom document
separates consistently from the top document, rotate the gap
adjustment knob counterclockwise another 1 or 2 clicks to
complete the adjustment.
12. Feed a stack of 50 to 100 documents twice through the transport
system. Verify the final count reflects the total number of
documents that were fed and that the counter shows the same
amount each time the documents are counted.
If the count is not the same, the gap is not adjusted correctly.
Rotate the gap adjustment knob counterclockwise another 1 or 2
clicks and repeat Step 12. Repeat until corrected.
13. Press Stop.
14. Enter function code F04 and disable Counting-only.
15. Press Enter.
Before you begin feeding documents into the scanner/microimager,
adjust the position of the feed shelf.
To semi-automatically feed multiple documents, the feed shelf should
be in the raised position (as shown above).
To raise the feed shelf:
1. Grasp the front of the feed shelf and lift it up.
2. Swing the height adjustment arm out and insert it into the groove
on the work shelf.
To hand-feed documents (one at a time), the feed shelf should be in
the down position (not shown).