D-Link xStack Reference Manual page 319

Web ui reference guide layer 2 managed gigabit ethernet switch
Hide thumbs Also See for xStack:
Table of Contents

Advertisement

®
xStack
DGS-3200 Series Layer 2 Managed Gigabit Ethernet Switch Web UI Reference Guide
swPktStormDisablePort
swIpMacBindingViolationTrap
swIpMacBindingIPv6ViolationTrap
MacBasedAuthLoggedSuccess
MacBasedAuthLoggedFail
MacBasedAuthAgesOut
FilterDetectedTrap
SingleIPMSColdStart
SingleIPMSWarmStart
SingleIPMSLinkDown
SingleIPMSLinkUp
SingleIPMSAuthFail
SingleIPMSnewRoot
SingleIPMSTopologyChange
The trap is sent when the port is disabled
by the packet storm mechanism.
When the IP-MAC Binding trap is
enabled, if there's a new MAC that
violates the pre-defined port security
configuration, a trap will be sent out.
When the IP-MAC Binding trap is
enabled, if there's a new MAC that
violates the pre-defined IPv6 IP-MAC
Binding configuration, a trap will be
sent out.
This trap is sent when a MAC-based
access control host is successfully
logged in.
This trap is sent when a MAC-based
access control host login fails.
This trap is sent when a MAC-based
access control host ages out.
This trap is sent when an illegal DHCP
server is detected. The same illegal
DHCP server IP address detected is just
sent once to the trap receivers within the
log ceasing unauthorized duration.
The commander switch will send
swSingleIPMSColdStart notification to
the indicated
The commander switch will send
swSingleIPMSWarmStart notification to
the indicated host when its member
generates a warm start notification.
The commander switch will send
swSingleIPMSLinkDown notification to
the indicated host when its member
generates a link down notification.
The commander switch will send
swSingleIPMSLinkUp notification to the
indicated host when its member
generates a link up notification.
The commander switch will send
swSingleIPMSAuthFail notification to
the indicated host when its member
generates an authentication failure
notification
The commander switch will send
swSingleIPMSnewRoot notification to
the indicated host when its member
generates a new root notification.
The commander switch will send
305
1.3.6.1.4.1.171.12.25.5.0.3
1.3.6.1.4.1.171.12.23.5.0.1
1.3.6.1.4.1.171.12.23.5.0.4
1.3.6.1.4.1.171.12.35.11.1.0.1
1.3.6.1.4.1.171.12.35.11.1.0.2
1.3.6.1.4.1.171.12.35.11.1.0.3
1.3.6.1.4.1.171.12.37.100.0.1
1.3.6.1.4.1.171.12.8.6.0.11
1.3.6.1.4.1.171.12.8.6.0.12
1.3.6.1.4.1.171.12.8.6.0.13
1.3.6.1.4.1.171.12.8.6.0.14
1.3.6.1.4.1.171.12.8.6.0.15
1.3.6.1.4.1.171.12.8.6.0.16
1.3.6.1.4.1.171.12.8.6.0.17