6-3-5 Input Selection of PID Control Target Value and Detection
Value
• The target value and detected value (feedback value) of PID control are set according to n004 for fre-
quency reference selection, n008 for local mode frequency reference selection, and n164 PID feed-
back input block selection as shown in the following diagram.
Make sure that the target value input and feedback value input do not overlap with each other. Setting
details are provided from the next page onward.
H Input Selection of PID Control Target Value
FREQUENCY adjuster of the
Digital Operator
Frequency reference 1 (n024)
External terminal (0 to 10 V)
External terminal (4 to 20 mA)
External terminal (0 to 20 mA)
Pulse train input
Communications frequency reference
Multi-function analog input (0 to 10 V)
Multi-function analog input (4 to 20 mA)
FREQUENCY adjuster of the
Digital Operator
Frequency reference 1 (n024)
H Input Selection of PID Control Detection Value
External terminal (0 to 10 V)
External terminal (4 to 20 mA)
External terminal (0 to 20 mA)
Multi-function analog input (0 to 10 V)
Multi-function analog input (4 to 20 mA)
Pulse train input
Local/Remote
Frequency reference 2 (n025)
Frequency reference 3 (n026)
Frequency reference 4 (n027)
Frequency reference 16 (n127)
Inching frequency (n032)
Feedback value
Chapter 6
Multi-step speed
reference
Target value
6-15