List of Parameters
Para
Reg-
Name
me-
ister
ter
No.
No.
(Hex)
Note Inverter overheating warning (setting value: 26) can be set for 5.5-kW and 7.5-kW Inverters only.
10-12
Description
19
Emergency
The Inverter stops
according to the set-
stop fault
(NO)
ting in n005 for inter-
ruption mode selection
with the emergency
stop input turned ON
stop input turned ON.
20
Emergency
NO: Emergency stop
stop warn-
with the contact
ing (NO)
closed.
NC: Emergency stop
with the contact
with the contact
21
Emergency
opened.
stop fault
Fault: Fault output is
(NC)
ON and reset with
RESET input. Warning
output is ON (no reset
output is ON (no reset
required).
22
Emergency
stop warn-
"STP" is displayed (lit
ing (NC)
with fault input ON and
flashes with alarm
input ON)
23
PID control
ON: PID control dis-
cancel
abled.
24
PID control
ON: Integral value
integral
reset.
reset
25
PID control
ON: Keeps integral
integral
value on hold.
hold
26
Inverter
ON: Displays inverter
(See
overheating
overheating warning
note)
warning
(oH3).
Chapter 10
Set-
Unit
Default
Chan-
ting
of
setting
ges dur-
range
set-
ting
opera-
Ref-
er-
ing
ence
page
tion