Figure 19 Power Control Menu screen
5.
Enter the command ON to power on the server, and enter YES when prompted to confirm the
action.
6.
Boot the operating system.
For more information, see the operating system documentation.

Powering on the server manually

NOTE:
If the power restore feature is set to Always On through the iLO 3 MP PR command, the
server automatically powers on to the full power state when the power cord is plugged in to the
server.
1.
Plug all power cables into the receptacles on the rear panel of the server.
2.
Press the power button to start the server.
3.
Start the operating system. For more information, see the operating system documentation.

Powering off the server

If the server is in the standby or full power state, power off the server by using either of the following
methods:
iLO 3 MP PC command
Power button

Powering off the server using the iLO 3 MP

1.
Gracefully shut down the operating system. See the operating system documentation for more
information.
2.
Initiate a console session, and access the MP Main Menu.
3.
Enter CM to enable command mode.
4.
Enter PC to use the remote power control command.
5.
Enter OFF to power off the server, and enter YES when prompted to confirm the action.
CAUTION:
standby power is still present in the server.
6.
Unplug all power cables from the receptacles on the rear panel of the server.
32
Installing the server
The main DC voltage is now removed from the system However, AC voltage for